GII T-25A

Brand: BMC

SKU: bpap0003

₹36,500.00

• RESmart GII BPAP System (T series) is a Bi-level Positive Airway Pressure device, which is intended to provide non-invasive ventilation for patients with obstructive sleep apnea (OSA), either in the hospital or at home. • The device is to be used only on the instruction of a licensed health care professional. Your home care provider will make the correct pressure settings according to your health care professional’s prescription. • Several accessories are available to make your OSA treatment with this device as convenient and comfortable as possible. To ensure that you receive the safe, effective therapy prescribed for you, use only BMC accessories.

Quantity

• A BIPAP is a Non invasive therapy it a pressure controlled in a spontaneous breathing. • It is used to help you breathe easier when you have condition that make breathing difficult . • Obstructive sleep apnea is a serious condition in which your breathing stop and starts repeatedly while you are asleep. • Chronic obstructive pulmonary disease (copd) • Asthma • Obesity hypoventilation syndrome. • Heart condition such as congestive heart failure or coronary artery disease • A neurological or neuromuscular disorder that affect your ability to breathe. • Poor breathing after a medical procedure such as surgery. • The machine works by pushing the pressurized air into your lungs. • It reduces burden on respiratory muscles and lungs to inhale and exhale • The machine motor blows air through the tube certain amount of required pressure. • The pressurized air enters your body through the mask or plugs. • It eliminates need for using a ventilator that makes uses of a tube that goes down into your throat without used for tracheotomy. • A tracheotomy is a procedure to create a hole in your neck to let you breathe through the trachea.

• Real time monitoring: Tidal Volume (Vt), Respiratory rate (Res Rate), Minute ventilation (Min Vent), Leakage (Leak) • Quick and easy operation • Slow and gentle Ramp • Innovative tracking technology for accurate and comfortable therapy • Unique sensitivity settings ensure better comfort during individual therapy • Auto on/Auto off function • Power off alert • Tube mask and disconnected alert • Automatic leakage and altitude compensation • Multi-language system • SpO2 Kit: Blood oxygen saturation and pulse rate display

Device Size

Dimensions: (L x W x H): 274 mm × 184 mm × 115 mm

Weight:1.9 kg

Water capacity: To maximum fill line 360 mL

Mode of OperationContinuous
Work ModeCPAP, AutoCPAP, S, AutoS, S/T, T
SD CardThe SD card can record patient data and fault information
AC Power Consumption

100 - 240 V ~, 50 / 60 Hz, 2.5A Max

100 - 240 V ~, 50 / 60 Hz, 2A Max

Main device input24V, 3.33A
Device offer to Heated Tubing Communications Port24 V ---- 18 W
Product Use, Transport and Storage
OperationTransport and Storage
Temperature: 5° C to 35° C (41˚F to 95˚F)-25° C to 70° C (-13˚F to 158˚F)
Humidity: 15% to 93% Non-condensing15% to 93% Non-condensing
Atmospheric Pressure: 760 ~ 1060 hPa760 ~ 1060 hPa
Heated Humidifier
Humidifier Settings:off, Auto, 1 to 5 (95˚F to 154.4˚F / 35°C to 68°C)
Humidifier Output:No less than 10 mg H2O/L
Environmental Conditions:Maximum airflow, 35°C, 15% relative humidity
Maximum Delivered Gas Temperature:≤ 43°C
Electric Shock
Type of Protection Against Electric ShockClass II Equipment
Degree of Protection Against Electric ShockType BF Applied Part
Degree of Protection Against Ingress of WaterIP22
Pressure Range
     ModelWork Mode                      Pressure Range
G2S B20A, G2S B20S, G2S B20T                IPAP               4.0 ~ 20.0 hPa
                EPAP               4.0 ~ 20.0 hPa
G2S B25A, G2S B25S, G2S B25T, G2S LAB                IPAP               4.0 ~ 25.0 hPa
                EPAP               4.0 ~ 25.0 hPa

         CPAP mode:     4.0 ~ 20.0 hPa

         Under single fault conditions, ≤ 30 hPa for CPAP, ≤ 40 hPa for the rest modes.

Pressure Display Accuracy± (0.8hPa+4%)
Static Pressure Stability± 0.5 hPa
RampThe ramp time ranges from 0 to 60 minutes.
Sound Pressure Level<30 dB, when the device is working at the pressure of 10 hPa.
Sound Power Level<38 dB, when the device is working at the pressure of 10 hPa.
Maximum Flow
Test Pressure (hPa)        4     9152025
Measured Pressure at the Patient Connection Port (hPa)      3        8141924

Average Flow at the Patient

Connection Port (l/min)

     90      120150150150
SpO2 Range:

0% ~ 100%

The margin of error for SpO2 between 70% and 100% is ± 3%.

 

No strict accuracy requirements for SpO2 below 70%.

Pulse RateRange: 40 ~ 240 BPM
Margin of Error: ± 1%
Wavelengths

Red: 663 nanometers

Infrared: 890 nanometers

Maximal Optical Output PowerLess than 1.5 mw maximum average.
Air TubingAir TubingLengthInner diameter
Tubing6 ft. (1.83m)19 mm
Heater Tubing6 ft. (1.83m)19 mm
The Form and the Dimensions of the Patient Connection PortThe 22 mm conical air outlet complies with ISO 5356-1.