0 Cart
No products in the cart.

Floton Auto CPAP

Brand: RESMED

SKU: scpap0006

₹26,000.00 ₹35,000.00

• Floton Auto CPAP comes on Automatic Positive Airway Pressure (APAP) treatment through most accurate pressure control which provides patient comfort. • It provides continuous positive airway pressure to the patient delivering optimal pressure breath by breath. • It includes Proprietary Expiratory Unloading Technique (EUT), equivalent to EPR, improves patient comfort by reducing expiratory pressure. • It includes the SD card to generate the report advanced data recording.
(Available)
Quantity

Categories: AUTO CPAP, CPAP

• Continuous positive airway pressure (CPAP) is a method for patient who have sleep apnea disorders.obstructive sleep apnea is a sleep disorders when your breathing stop and starts. • Obstructive sleep apnea causes interruption breathing often because your throat or airway temporarily block them. • A CPAP machine works a compressor motor generates a continuous steam of pressurized air that travel through an air filter into a flexible tube. • The machine works on a steady floe of pressurized air into your nose and mouth as you sleep it keep your airways helps breathe normally. • The airstream from the CPAP machine pushes against any blockages opening your airways so your lungs receives plenty of oxygen. • It improves your ability to sleep without walking up. • It lowers your risk of having a heart attack stroke or other cardiovascular attack. • It hepls lower your blood pressure. • It reduces daytime sleepiness. • It may reduce blood glucose and cholesterol level. • Blood pressure • Heart disease • Reduce stroke risk • Upper airway resistance syndrome
• Expiratory Unloading Technology, an exhalation relief function making breathing more comfortable and feel close to nature. • When using the ramp function the pressure starts at 4cmH2O and rises until the device reaches the set PAP RAMP setting is between 0-60min and increase in pressure is 1 cm of water step per minute • The Floton Auto will record up to 6 months of the following therapy information to the on-board memory. • The Auto On / Off feature allows the Floton Auto to detect when the mask is on and the user is breathing. The machine automatically begins providing the therapy air stream without having to press a button. This feature may be turned off if desired. • Compact, light, Quiet • Accurate pressure control

 power supply unit

AC input range: 100–240V, 50–60Hz 1.0–1.5A, Class II 115V, 400Hz 1.5A, Class II (nominal for aircraft use) DC output: 24V 3.75A Typical power consumption: 53W (57VA) Peak power consumption: 104W (108VA)

Environmental conditions

Operating temperature: +5°C to +35°C Note: The air flow for breathing produced by this therapy device can be higher than the temperature of the room. Under extreme ambient temperature conditions (40°C) the device remains safe. Operating humidity: 10 to 95% relative humidity, non-condensing Operating altitude: Sea level to 2,591 m; air pressure range 1013 hPa to 738 hPa Storage and transport temperature: -20°C to +60°C Storage and transport humidity: 5 to 95% relative humidity, non-condensing

Electromagnetic compatibility

The AirStart 10 complies with all applicable electromagnetic compatibility requirements (EMC) according to IEC60601-1-2:2007, for residential, commercial and light industry environments. It is recommended that mobile communication devices are kept at least 1 m away from the device.

Sensors

Pressure sensor: Internally located at device outlet, analogue gauge pressure type, -5 to +45 cm H2O (-5 to +45 hPa) Flow sensor: Internally located at device inlet, digital mass flow type, -70 to +180 L/min

Maximum single fault steady pressure

Device will shut down in the presence of a single fault if the steady state pressure exceeds: 30 cm H2O (30 hPa) for more than 6 sec or 40 cm H2O (40 hPa) for more than 1 sec.

Sound

Pressure level measured according to EN ISO 17510-1:2009 (CPAP mode): SlimLine: 26.6 dBA with uncertainty of 2 dBA Standard: 26.6 dBA with uncertainty of 2 dBA Power level measured according to EN ISO 17510-1:2009 (CPAP mode): SlimLine: 34.6 dBA with uncertainty of 2 dBA Standard: 34.6 dBA with uncertainty of 2 dBA

DIMENSIONS

116 mm x 205 mm x 150 mm

Temperature

Maximum heater plate: 68°C Cut-out: 74°C Maximum gas temperature: £ 41°C

Air filter

Standard: Material: Polyester non woven fibre Average arrestance: >75% for ~7 micron dust Hypoallergenic: Material: Acrylic and polypropylene fibres in a polypropylene carrier Efficiency: >98% for ~7-8 micron dust; >80% for ~0.5 micron dust

Operating pressure range APAP, CPAP

4 to 20 cm H2O (4 to 20 hPa)

Supplemental oxygen Maximum flow

4 L/min

NOTE

The manufacturer reserves the right to change these specifications without notice.

· Do not use electrically conductive or antistatic air tubing.

 

 · The temperature and relative humidity settings displayed are not measured values.

 