• The BMC P2H Pillows mask is also compatible with the ResMed Air Mini provided you have the 15mm connector provided with this pack. • The P2H CPAP Mask is designed to work with almost any CPAP Machine and can be used without the regular water-based CPAP humidifier. • Optimized for use with the BMC M1 Mini Travel Auto CPAP device with a powerful HME (Heat and Moisture Exchange) Humidification. • The BMC P2H pillows nasal mask pack provides everything you need to connect the BMC M1 Mini device. • The New BMC P2H is a small, lightweight nasal pillow mask that incorporates HME (heat moisture exchange) technology for waterless humidification. • They are most commonly used with travel CPAP machines which do not have an inbuilt humidifier system. • HME filters capture water content from your breathing and use it to create humidification. • It’s a great mask option for those who use a travel CPAP machine.
Categories: MASK, WATERLESS HUMIDIFICATION NASAL MASK
• Nasal pillow mask are cushions that seal at the base of the nostrils and are help in place with a stretchy strap that goes around the back on head. • It reduce air leakage since they direct air into the patients nasal passangers. They work well for patient with a beard or mustache. • Nose breathers. • It lots of facial hair that with other mask types can prevent the mask from making seal with your skin • Active sleepers • It may cause nasal dryness or nose bleeds. • More natural airflow than nasal pillow as the deliverd pressure isn’t direct. • Better for higher pressure setting than nasal pillow. • It may experience higher incidences of nose bleeds or nasal dryness due to direct air pressure.
• Minimalism design, easy to clean, assemble and fir. • The Lightness makes everything under control. • Wide-vision design contributes to convenient reading • 3 cushion sizes are available for your appropriate option • The BMC P2H Nasal pillow mask is ideal for patients who sleep with their mouth closed and can exhale through the nostrils. • Incorporates HME (heat moisture exchange) technology for waterless humidification. They are most commonly used with travel CPAP machines which do not have an inbuilt humidifier system. • HME filters capture water content from your breathing and use it to create humidification. It’s a great mask option for those who use a travel CPAP machine.
PRESSURE FLOW CURVE |
|
DEAD SPACE INFORMATION |
Dead space is the empty volume of the nasal pillow and the short tube assembly up to the swivel. The dead space of the P2H for large pillow is 45 ml |
THERAPY PRESSURE |
4 to 25cm H20 |
RESISTANCE |
Drop in pressure measured (average for 3 sizes) At 50L/Min:Humidifier:0.8 cm H20 Humidifier:0.5Cm H20 At 100L/Min:2.2Cm H20 Humidifier:1.3Cm H20
|
SOUND |
Declared dual number noise emission values accordance with 150.4871.The A- Weighted sound power level of the interface is 28dba with uncertainly 5dba. The A-Weighted sound pressure of the interface at a distance of 1m is 20 dba with uncertainly 5dba. |
ENVIRONMENTAL CONDITIONS |
Operating temperature:+5c to +4c (41deg F to 104degF) Operating humidity :0%~93% Relative humidity non condensing Storage and transport :20deg c to +55deg c(-4deg F to 131deg F) Storage and transport humidity: 0%~93% relative humidity non condensing |
PRESSURE FLOW CURVE |
|
DEAD SPACE INFORMATION |
Dead space is the empty volume of the nasal pillow and the short tube assembly up to the swivel. The dead space of the P2H for large pillow is 45 ml |
THERAPY PRESSURE |
4 to 25cm H20 |
RESISTANCE |
Drop in pressure measured (average for 3 sizes) At 50L/Min:Humidifier:0.8 cm H20 Humidifier:0.5Cm H20 At 100L/Min:2.2Cm H20 Humidifier:1.3Cm H20
|
SOUND |
Declared dual number noise emission values accordance with 150.4871.The A- Weighted sound power level of the interface is 28dba with uncertainly 5dba. The A-Weighted sound pressure of the interface at a distance of 1m is 20 dba with uncertainly 5dba. |
ENVIRONMENTAL CONDITIONS |
Operating temperature:+5c to +4c (41deg F to 104degF) Operating humidity :0%~93% Relative humidity non condensing Storage and transport :20deg c to +55deg c(-4deg F to 131deg F) Storage and transport humidity: 0%~93% relative humidity non condensing |