• The HFNC oxygen therapy is carried out using air \ oxygen blender, active humidifier single heated tube and nasal cannula it is respiratory support. • The HFNC continuous to increase easily set up it may also create positive pharyngeal pressure to reduce work of breathing the device midway classical oxygen delivery system like high concentrations CPAP generators . • It is designed a heated humifided mixture of air and oxygen at a high flow than the inspiratory flow. • It adjust the flow rate and body weight provides a degree of distending pressure. It also decrease works of breathing and oxygenation. • It utilizes a soft large bore nasal prongs it is similar to used on mechanical ventilator with the HFNC. It overcome the leading causes of discomfort seen with conventional oxygen therapy. • It is a difficult quality level of PEEP generated by the high flow. It support breathing in people with acute heart failure, Acute respiratory distress syndrome. • It avoids rebreathing of co2 gas and therefore decreased anatomize dead space. It promoted a slow and deep breathing .it airway hydrated and it improved mucus clearance. • This improves FRC and reduce work of breathing it flows used are high humidification is necessary to avoid drying of respiratory secretions and for maintaining nasal cilia function. • It is mild positive airway pressure and lung volume recruitment. • It will titrate FIO2 and flow to promote comfort and oxygen saturation. It ensure the monitor spo2 saturation and pleth wave form. • It ensure maintain a O2 saturation on mask • It delivery of optimally humidified and warm gases • It decreased body energy expenditure. • It is used for intubation and extubation support as well as treatment and prevention of post operative respiratory failure and for oxygenation patients during trails or bronchoscopy.

Quantity

• HFNC prongs are highly in demand for the treatment and support therapy for covid patients. • The humidified air oxygen is very helpful in hypoxic patients with FiO2 levels lesser than 90% high flow oxygen therapy. • High Flow Nasal Cannula belongs to an oxygen therapy method, which provides a high concentration, high flow rate, close to relative humidity gas delivery to the patient through these three types of interface which depends on patient different conditions, especially to the slightly breathing disorder or recovery period patients. • Reduces of dead space and increases alveolar ventilation, and supports positive airway pressure. • Improves mucocilliary clearance and promotes sputum discharge. • Promotes improved patient compliance. • Maintains a relatively stable state and oxygen concentration is adjustable.

• The HFNC is the soft materials and low noise design giving comfortable treatment experience. • It silicone prongs gives more soft and comfortable touch feeling. • It has clip fixing cannula to keep stability. • The bilateral are designed under the stability good air permeability • The nasal cannula consists of rhinobyon, headband, tube and lanyard. • The product consists of three specifications: large size (NC10L), medium size (NC10M) and small size (NC10S)

Package Included
  • F20 connector for AirMini
  • HumidX cartridge
  • HumidX Plus cartridge
  • AirMini tube
Package Dimensions30.8 x 11.8 x 5.2 cm;
Product Weight350 Grams

Environment Conditions

Operating temperature5° C to +35°C
Operating humidity10% to 95% RH non-condensing
Operating altitudeSea level to 8,500' (2,591 m); air pressure range 1013 hPa to 738 hPa
Storage and transport temperature-25°C to + 70°C
Storage and transport humidity5 to 95% relative humidity, non-condensing

Sound Level

Pressure level measured according to ISO 80601-2-70:2015 (CPAP mode)30 dBA with uncertainty of 2 dBA
Power level measured according to ISO 80601-1-70:2015 (CPAP mode)38 dBA with uncertainty of 2 dBA
Sound pressure levelAir tubing connected to AirMini F20 connectors with mask is 19 dBA with uncertainty of 3 dBA
Sound Power levelAir tubing connected to the AirMini F20 connectors with mask 27 dBA with uncertainty of 3 dBA

Air filter

StandardMaterial: Polyester non woven fibre Average arrestance: >75% for ~7 micron dust
HypoallergenicMaterial: Acrylic and polypropylene fibres in a polypropylene carrier Efficiency: >98% for ~7-8 micron dust; >80% for ~0.5 micron dust

AirMini air tubing

MaterialFlexible plastic
Length1.9 m
Inner diameter15 mm